AK-609 Emergency Battery Pack For Led's

• Emergency backup units for LED lamps
• It can be used with an armature mounted inside or with an external box.
• Supplied with Ni-Cd Battery.
USAGE AREAS
• LED lighting fixtures
• Emergency lighting and guidance fittings
• Waterproof type LED lighting fixtures
• Special design led lighting fixtures
• Recessed type luminaires
BODY STRUCTURE
• Body - Electrostatic powder coated aluminum case. ABS plastic covers.
BATTERY
• BATTERY - Nickel-cadmium in all models
OPTIONS
• Model choices according to lamp type and power
• 1-2 hour emergency backup times
PRODUCT DOCUMENT
  PRODUCT INFORMATION
AK-609 model emergency backup modules;
• 9w is connected to the supply input of the LED drivers which can operate with DC voltage below.
• There are models connected between the led drive and the led panel or directly connected to the led driver input.
• Maximum 5 may switch the DC LED current.
• 6 volt ni-cd battery, are plug-in type terminals.
• It should be installed inside the armature or in the external box.
• It does not have standard output current, special production according to lamp, backup time and lamp safety are provided in this way.
• Provides power failure backup for LED lamps.
• It makes a backup at power failure.
• Battery charging indicator.
• The lamp's 2 connections are switched at once.
• With fully insulated supply circuit and the lamp contacts, there is no damage due to the different phase connections.
• Continuous charging method keeps the battery pack full and ready.
• Appropriate kit should be selected according to the lamp.
• Plug-in type latching type terminals are used for easy installation.
• The mains supply voltage is standard 220 volts AC 50 Hz.
• Charging time for first use is 24 hours.
• It can withstand fluctuations up to 285 volts at mains voltage.
• Switches to emergency lighting mode under 150 volts, charging over 185 volts
• It is manufactured according to TS 8710 EN60598-2-22 standard in the framework of ISO 9001-2000 quality management system.
  TECHNICAL DRAWINGS
  PRODUCT FEATURES
EMERGENCY BATTERY PACKS FOR LED LIGHTS
MODEL CODE   LIGHTING STYLE USAGE TYPE LAMP  DURATION BATTERY WEIGHT
(Batt. inc.)
IP
CLASS
ISOLATION CLASS OPERATION
TEMP
POWER CONSUMPTION OPERATING VOLTAGE
AK-312-1 Non-maintained  Internal 12 volt LED lamp Emergency 60 min.  3 cell AA size 0,28kg 30 I -16/+40° 1,5 watt 220-240
AK-312-2 Non-maintained  Internal 12 volt LED lamp Emergency 120 m.  3 cell SC size 0,35kg 30 I -16/+40° 1,5 watt 220-240
AK-312-3 Non-maintained  Internal 12 volt LED lamp Emergency 180 m.  3 cell SC size 0,38kg 30 I -16/+40° 1,5 watt 220-240
AK-4600-1 Non-maintained  Internal 3,5-70 volt LED lamp Emergency 60 min.  4 cell AA size 0,27kg 30 I -16/+40° 1,5 watt 220-240
AK-4600-3 Non-maintained  Internal 3,5-70 volt LED lamp Emergency 180 m.  4 cell SC size 0,37kg 30 I -16/+40° 1,5 watt 220-240
AK-7200-1 Non-maintained  Internal 3,5-200 volt LED lamp Emergency 60 min.  6 cell AA size 0,33kg 30 I -16/+40° 1,5 watt 220-240
AK-7200-2 Non-maintained  Internal 3,5-200 volt LED lamp Emergency 120 m.  6 cell SC size 0,5kg 30 I -16/+40° 1,5 watt 220-240
AK-7200-3 Non-maintained  Internal 3,5-200 volt LED lamp Emergency 180 m.  6 cell SC size 0,5kg 30 I -16/+40° 1,5 watt 220-240
AK-609W-1 Non-maintained  Internal 110-220 volt AC led lamba Emergency 60 min.  5 cell SC size 0,45kg 30 I -16/+40° 3,5 watt 220-240
AK-609W-2 Non-maintained  Internal 110-220 volt AC led lamba Emergency 120 m.  5 cell D size 0,75kg 30 I -16/+40° 3,5 watt 220-240
AK-4600S-1 Non-maintained  Internal 3,5-70 volt LED lamp Emergency 60 min.  6 cell AA size 0,27kg 30 I -16/+40° 1,5 watt 220-240
AK-4600S-3 Non-maintained  Internal 3,5-70 volt LED lamp Emergency 180 m.  6 cell AA size 0,30kg 30 I -16/+40° 1,5 watt 220-240
AK-4600S-EKO Non-maintained  Internal 12-65 volt LED lamp Emergency 180 m.  6 cell AA size 0,27kg 30 I -16/+40° 1,5 watt 220-240